Brass Stamped Electrical Contacts
Brass Stamped Electrical Contacts

Brass Stamped Electrical Contacts

Brass stamped electrical contacts do not serve as "arc-bearing surfaces"—as silver contacts do—but rather act as the "structural framework" within the conductive circuits of electrical devices. In a relay, such a contact may function as the terminal connecting the coil to the external pins; in a switch, it serves as the fixed guide rail for the sliding contact; and in a contactor, it acts as the wiring busbar or the conductive bridge located within the arc-extinguishing chamber.
Send Inquiry

Products Description

 

Brass Stamped Electrical Contacts

 

Brass Stamped Electrical Contacts are electrical components produced through a precision stamping process, in which brass material is fabricated into conductive connecting parts. Primarily utilized within low-voltage electrical devices-such as relays, switches, and contactors-these components serve to facilitate stable current flow, signal transmission, and electrical connectivity.

These products combine excellent electrical conductivity with structural integrity and stability in mass production. Consequently, they are well-suited for industrial electrical systems that demand high standards regarding dimensional consistency, contact reliability, and assembly efficiency.

 

 

Core Advantages

Exceptional Stress Relaxation Resistance

When subjected to appropriate heat treatment, high-quality Electrical Connector Socket Brass Stamping maintain stable contact normal force under prolonged compressive loads, effectively preventing poor contact caused by spring force decay.

 

Superior Forming Precision and Consistency

Leveraging precision progressive dies, we ensure that-even in high-volume production-the contour dimensions, hole positions, and spring-back angles of every Plug Socket Brass Stamping remain highly consistent, thereby meeting the requirements for automated assembly.

 

Robust Base Material for Arc Erosion Resistance

Although brass itself possesses lower inherent resistance to arc erosion compared to silver, it serves as an excellent substrate capable of rapid heat dissipation; when combined with a surface coating, Brass Stamping Switch Terminal Accessories effectively disperses arc energy, thereby extending the overall service life of the component.

 

 

Brass Strip for Brass Stamped Electrical Contacts

 

 

Application Scenarios

 

Industrial Control Relays Electrical Metal Brass Stamping Parts are used as the core conductive contacts in electromagnetic and solid-state relays; designed to handle the high-frequency switching demands of PLC control loops and motor control circuits, ensuring stable switching between signal and load circuits.
Low-Voltage Distribution Switches

Electric Brass Stamping Part for Wall Switch Socket serves as the conductive components in miniature circuit breakers, disconnectors, and transfer switches; responsible for making and breaking distribution circuits while meeting the current-carrying requirements of lighting and power circuits.

AC Contactors Electrical Connector Socket Brass Stamping is employed as contactor contacts in motor control and capacitor compensation circuits; capable of withstanding the high inrush currents associated with motor startup as well as the arcing generated during circuit interruption, thereby ensuring reliable conductivity in scenarios involving frequent starting and stopping.

 

Brass Stamped Electrical Contacts for High Voltage DC EV/HEV Relay/Contactor

 

 

Technical Features

Material Directionality Control

 

Brass strip for Plug Socket Brass Stamping develops a fibrous grain structure during the rolling process. During layout design, all critical bend lines are oriented perpendicular to the rolling direction to minimize the risk of cracking during bending.

Die Clearance Matching

 

The blanking clearance is set at 5–8% of the material thickness for Brass Stamping Switch Terminal Accessories. Insufficient clearance accelerates die wear and increases blanking force; excessive clearance results in increased burrs and torn cut edges. For H62 brass with a thickness of 0.8 mm, a single-sided clearance of 0.04–0.06 mm is recommended.

Stress Relief Aging

 

For Electrical Metal Brass Stamping Parts requiring multiple bends or complex forming, a low-temperature annealing treatment (150°C for 2 hours) is performed after stamping to relieve internal stresses and prevent dimensional creep during storage (particularly for elastic components).

Brass Stamped Electrical Contacts processing

 

 

 

contact us

 

We specialize in the supply of stamped brass electrical contacts, offering both standard off-the-shelf products and custom-engineered solutions. We provide expert selection guidance, sample testing services, and reliable, consistent delivery for bulk orders. Our products are designed to meet the diverse requirements of various low-voltage electrical equipment applications. We welcome inquiries and technical consultations from engineering and procurement professionals.

 

Mr Terry from Xiamen Apollo

Hot Tags: brass stamped electrical contacts, China brass stamped electrical contacts manufacturers, suppliers, factory, Electrical Contact Assemblies Brass Stamped Parts, CuZn Brass Stamping, Electrical Contact Stamping Brass Part, Cold Stamping Brass For Switch, Electrical Brass Switch Socket Part, Electric Brass Stamping Part