Electric Double Metal Contact
Electric Double Metal Contact

Electric Double Metal Contact

Electric Double Metal Contact is a bimetallic contact component designed for high current and high frequency switching scenarios. It uses copper alloy and stainless steel composite materials, and achieves excellent conductivity, wear resistance, and thermal stability through precision stamping and surface treatment technology. The product is widely used in industrial circuit breakers, contactors, relays, automation control equipment, and other fields.
Send Inquiry

Products Description

 

Products profile
 

In modern electrical systems, Electric Double Metal Contact, as a key electrical connection component, plays an irreplaceable role in ensuring the stable and efficient operation of circuits. Whether it is industrial automation equipment, building electrical facilities, or various electronic devices, reliable electrical AgCuAg Tri-metal Contact Rivets performance is the core element to ensure the normal operation of equipment, improve production efficiency, and ensure the safety of personnel and equipment.

 

Our Electric Double Metal Contact is specially designed to meet the needs of professional buyers and engineering customers for high-quality electrical connection solutions. With excellent manufacturing technology, strict quality control, and innovative design concepts, it stands out in the fierce market competition and is committed to providing reliable electrical connection guarantees for your projects.

Electric Double Metal Contact
 

Breakthrough advantages of composite materials

 

1. Bimetallic composite structure | Perfect balance of conductivity and mechanical strength
Technical principle: The composite structure of copper matrix (high conductivity) + silver alloy coating (high corrosion resistance/wear resistance) combines the excellent conductivity of copper with the high temperature resistance and arc erosion resistance of silver alloy.
Quantitative advantages:
Conductivity ≥ 95% IACS (International Annealed Copper Standard), which is more cost-effective than pure silver contacts.
Coating thickness is adjustable from 0.1 to 0.5 mm to meet different current load requirements (such as 10A to 500A).
Tensile strength ≥ 200MPa, mechanical life of more than 100,000 times (IEC 60512 standard test).

 

We are professional in manufacturing Electric Double Metal Contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


​​2. Arc erosion resistance | Extend contact life and reduce maintenance costs

Technical highlights: Silver alloy coatings (such as AgSnO₂, AgCdO) have high melting points and self-lubricating properties, which can effectively resist arc erosion and reduce Three-Compound Contact surface wear.

Quantitative advantages:
Under AC 220V/10A conditions, the arc erosion rate is ≤​​0.02mm/10,000 times (industry average ≥0.05mm).

Life test reaches 500,000 times of switching, which is more than 3 times higher than traditional pure copper contacts.

Applicable to equipment with frequent start and stop (such as elevators, inverters), and the maintenance cycle is extended by 50%.
​​
​​3. Wide temperature range stability | Adapt to extreme environment applications
​​Material properties: Both the copper substrate and the silver alloy coating have passed the -40℃~+125℃ temperature cycle test, without the risk of embrittlement or deformation.
​​Quantitative advantages:
Trimetal Moving Contact resistance fluctuation under high temperature conditions (+125℃) ≤±5% (industry average ≥±10%).
In a low temperature (-40℃) environment, it still maintains more than 85% of the initial conductivity.

 

Application scenarios | Accurately match customer needs
 
 
 

Industrial control

relays, contactors, circuit breakers (such as Schneider, ABB compatible models).

 
 

New energy vehicles

battery management system (BMS), charging gun, Trimetal Silver Contacts (support high pulse current).

 
 

Home appliances

air conditioning compressor starter, washing machine motor switch.

 
 

Power equipment

high-voltage disconnector, photovoltaic inverter, DC contactor.

 

Electric Double Metal Contact and Their Applications

Why choose us? | Manufacturing advantages and value-added services
 

Vertical integration production, 

One-stop completion from copper stamping to silver alloy plating, reducing outsourcing links and reducing costs by 15% for Trimetal Electric Contacts.

Engineer team support

Free Tri Metal Contact Rivet selection calculation (current density, temperature rise simulation) to shorten the customer design cycle.

Flexible customization

Support non-standard sizes, special plating (such as Au/Ni), and packaging requirements (anti-static bags/trays) for Double Sides Contacts.

WHY CHOOSE US---YOUR GET WHAT YOUR PAY FOR

 

 

Contact us

 

Mr. Terry from Xiamen Apollo

Hot Tags: electric double metal contact, China electric double metal contact manufacturers, suppliers, factory, Electrical Trimetal Silver Contacts, Tri metal Silver Rivet Contacts, Trimetal Electrical Contacts, Trimetal Electrical Rivets, Trimetal Rivet Contacts For Electrical, Trimetal Silver Contacts